• Fully Automatic Transformer Oil Tan Delta Tester

  • Fully Automatic Transformer Oil Tan Delta Tester

  • Fully Automatic Transformer Oil Tan Delta Tester

  • Fully Automatic Transformer Oil Tan Delta Tester

Fully Automatic Transformer Oil Tan Delta Tester

Fully automatic Oil Tan Delta Tester is used for testing tangent delta value,dielectric loss factor and DC resistivity of insulation transformer oil and other liquid insulating medium.

Product Description

Fully Automatic Transformer Oil Tan Delta Tester Application:

Insulating oil tangent delta and resistivity tester,also called Automatic Precision Oil Dissipation Factor Tester or oil tan delta tester, which is used for testing tangent delta value,dielectric loss factor and DC resistivity of insulation transformer oil and other liquid insulating medium. 

The instrument is characterized by integrated structure, and integrates the dielectric loss of grease cup, temperature controller, temperature sensor, dielectric loss test bridge,AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. It is equipped with large screen LCD display. The test results can be automatically stored and printed out so that the operator with no professional training will be able to use it easily.

Features:

1. Grease cup complies to national standard GB/T5654-2007; three-electrode structure; inter-electrode space of 2mm; eliminate stray capacitance and leakage effects on dielectric loss test results.

2. Adopts the medium frequency induction heating and PID temperature control algorithm with advantages of non-contact oil cup and heating body, even heating, fast speed, convenient control, strict temperature control.

3. Internal standard capacitor of SF6 gas-filled three-electrode capacitance of the capacitor dielectric loss and electrical capacity independence of ambient temperature, humidity and other effects. The instrument accuracy is ensured even after prolonged use.

4. AC test power supply using AC-DC-AC conversion to effectively avoid fluctuations in mains voltage and frequency effect on dielectric loss measurement accuracy. Even a generator, the instrument can work properly.

5. Perfect protection function. When there is over voltage, over current or high-voltage short circuit, instrument can quickly cut off pressure and issues a warning message. When the temperature of the sensor fails or is not connected, the instrument will also issue a warning message.

6. There is a temperature limit relay in the medium frequency induction heating furnace. When temperature is above 120 degrees, the instrument frees the relay and stops heating.

7.More convenient the experimental parameter is set.Temperature setting range 0~125℃, AC voltage setting range 500~2200V, DC voltage setting range 0~500V.

8. With large screen LCD with backlight and clear display. Friendly interface; Enter the commands, the instrument will automatically test, store and print test results.

9. Built-in real-time clock. Test date ans time can be retained with the test results, display and print.

10. Air electrode cup calibration function. Measurement air electrode cup capacitance and dielectric loss factor in order to determine air electrode cup cleaning and assembly condition. The calibration data is automatically saved in order to facilitate the calculation of relative permittivity and DC resistivity.

Specification:

Display

English LCD

Capacitance

5pF-200pF

Measuring range

Capacitance:5pF~200pF

Relative permittivity: 1.000-30.000

Dielectric loss factor: 0.00001-100

DC resistivity: 2.5 MΩm-20 TΩm

Measurement accuracy

Capacitance: ± (1% reading + 0.5pF)

Relative permittivity: ±1% reading

Dielectric loss factor ± (1% reading + 0.0001)

DC resistivity: ±10% reading

Resolution

Capacitance: 0.01pF

Relative permittivity: 0.001

Dielectric loss factor: 0.00001

Temperature range

0-125 ° C

Temperature measurement error

±0.5 °C

AC experimental voltage

500-2200V,continuously adjustable, frequency: 50Hz

DC test voltage

0-500V, continuously adjustable

Power consumption

100W

Power supply voltage

 AC 220V ± 10%(can be customized)

Power frequency

Ambient temperature

50Hz/60Hz ±1%(can be customized)

0-40 °C

Relative humidity

<75%

Dimensions

500 × 360 × 420mm

Your inquiry will be replied within 12 hours due to time difference.

Please contact for more technical details and latest price

  • wechat

    Joanna Hu: hopujoanna

Chat with Us