Product Description
Oil BDV Tester Introduction:
HJT-A series advanced type fully automatic transformer oil breakdown voltage tester is applied to test the insulating oil's dielectric strength, It widely used in many power systems, railway systems, large-scale petrochemical plants and enterprises,which have a lot of electrical equipment whose internal insulation are mostly oil-filled insulation type.It is designed as per the requirement of National standard GB / T507-2002, industry standard DL429.9-91 and the latest power industry standard DL / T846.7-2004, international standard IEC 156, IEC 60296,ASTM D 1816,etc
Main features:
1. The instrument is controlled by single chip microcomputer with large capacity, and works stably and reliably;
2. The instrument is equipped with temperature, humidity and clock display functions,Customized infrared oil temperature measurement;
3. The instrument is equipped with a wide range of watchdog circuit to eliminate the phenomenon of dead machine;
4. Various operation options. Instrument built-in GB/IEC standard and customized operation, which can adapt to various choices of different users;
5. The instrument oil cup is cast and formed by special glass in one time, eliminating the occurrence of interference phenomena such as oil leakage;
6. The unique high-voltage sampling design of the instrument allows the test value to directly enter the A/D converter,avoiding errors caused in the analog circuit and making the measurement results more accurate;
7. The instrument has internal protection functions such as over current, over voltage and short circuit, and has strong anti-interference ability and good electromagnetic compatibility;
8. Instrument self-analysis function, assist operator to judge sample oil;
9. USB and RS232 interface;
10. Large colorful touch screen;
11. Portable structure, easy to move, indoor and outdoor use is very convenient.
Technical Specs:
HJT-A Insualting Oil BDV Tester |
||
Technical Guidance
|
Booster capacity |
1.5 kVA |
Boost speed |
0.5kV/s-5.0kV/s (Increment every 0.5)Ten gears optional |
|
Error |
0.2 kV/s |
|
Output voltage |
0 ~ 100 kV |
|
Voltage accuracy |
±(2% reading + 2 words) |
|
Power supply distortion rate |
< 1% |
|
Electrode gap |
standard 2.5mm |
|
Test times |
6 times (1-9 times optional) |
|
Resting time |
900S (0-9000 S optional) |
|
Interval static time |
300S (0-900 S optional) |
|
Stirring time |
15S (0-250S optional) |
|
Working Condition |
Environmental temperature |
0 ~ 40℃ |
Relative humidity |
≤85% |
|
Working power |
AC 220V(1 ± 10%) |
|
Power frequency |
50 Hz (1 ± 10%) |
|
Power consumption |
< 200w |
|
Weight and Dimension |
Overall dimension |
650mm×470 mm×410 mm |
Weight |
42 kg |